KULUN / DC Power Supply

DCA IGBT DC Power Supply Module (Water-cooled)

KULUN DCA-IGBT module: drawer-type water-cooled DC power module rated to 60 kW for DC heating, electrolysis, electroplating and crystal furnaces.

Output Voltage RangeDC 6–800 V (custom)
Output Current RangeDC 100–2000 A

产品特征

  • Modular drawer design — easy to combine, install and maintain

  • Compact, lightweight, high power factor and efficiency

  • Parallel N+1 redundancy for higher system reliability

  • IGBT inverter technology with high-speed microprocessor control

  • Constant voltage, constant current or constant power operation

  • High-efficiency soft-switching — efficient, low-noise, reliable

  • Full protection: short circuit, overload, overheating, overvoltage, overcurrent

技术参数

Input

Mains supply

Three-phase AC 380 V, 45–65 Hz

Control supply

AC 85–265 V, 50/60 Hz

Output

Output voltage

DC 6–800 V, customized

Output current

DC 100–2000 A

Performance

Power factor

≥0.95 (full load)

Efficiency

80–92% (full load)

Key features

Closed-loop mode

Open loop, constant current, constant voltage or constant power, selectable

Cooling

Water cooling

Setpoint

DC 0/4–20 mA, DC 0–5 V/10 V, communication

Inputs

4 analog inputs, 4 digital inputs

Outputs

2 relay outputs, NO contact, AC 240 V/3 A, DC 24 V/5 A

Communication

Modbus RTU, PROFIBUS, PROFINET

Duty

Continuous duty

Soft start / stop

0–300 s

Protection

DC bus fault

Protection on DC bus undervoltage or overvoltage

Output short circuit

Protection on output short-circuit fault

Overheating

Protection when device temperature > 85 °C

Overcurrent

Protection when output current reaches the set multiple

Load break

Protection when load current falls below the threshold setting

典型应用

Electrolysis & Electroplating

Stable DC supply for electrolysis, electroplating and surface treatment; output voltage, current and control configured to the bath, electrodes and process curve.

Steel Cold Rolling & Surface Treatment

For stainless steel electrolytic pickling, electrolytic cleaning and degreasing, and tin/zinc plating lines — configured to line cycle, load and cooling conditions.

Industrial Heating & Monocrystal Furnaces

DC heating loads needing fast power regulation, including monocrystal furnaces and other industrial heaters.

Smelting, Pickling & Water Treatment

Continuous-duty industrial DC applications; selected by load capacity, control interfaces and protection requirements.

FAQ

What type of DC power supply is the DCA?

A water-cooled DC power module using IGBT high-frequency inversion — the building block of industrial DC supply systems.

Which industries use the DCA?

Electrolysis & electroplating, steel metallurgy, DC heating, monocrystal furnaces, non-ferrous metals, surface treatment and water treatment.

DCA vs. SCR DC supplies?

DCA uses IGBT high-frequency switching — smaller, lighter, faster dynamics. SCR suits different load and process boundaries. Choose by ripple, environment, maintenance and capacity.

Power per module?

Up to 60 kW. System capacity is set by output voltage, current, redundancy and site conditions.

Can modules be paralleled for more capacity?

Yes — the modular structure supports multi-module parallel configurations with room for later expansion.

Is N+1 redundancy supported?

Yes, per project. Whether and how much redundancy depends on continuous-duty requirements and maintenance strategy.

Which control modes are supported?

Constant current, constant voltage and constant power — the actual mode follows the process load and control requirements.

Can it connect to PLC or a host system?

Yes — analog, digital or communication interfaces connect to PLC, DCS or SCADA hosts per project.

Can it be used for hydrogen projects?

Yes for water electrolysis and similar DC supply; configure to electrolyzer voltage, current, start/stop mode, process curve and interlocks.

Which cold-rolling processes does it serve?

Stainless steel electrolytic pickling, electrolytic cleaning, electrolytic degreasing, tinning and galvanizing — confirmed against line equipment and load parameters.

How is cooling determined?

This is a water-cooled module; provide site water quality, temperature, pressure, piping and ambient temperature to confirm the cooling configuration.

What to provide for selection?

Output voltage, current, load type, duty cycle, control mode, communication, installation environment and cooling conditions; electrolysis projects also need the process curve and start/stop requirements.

选型咨询

请提供应用行业、设备工况、电压电流、功率范围和现场环境,工程师将协助确认方案。

在线留言
您好,请留下您的咨询需求,我们会尽快与您联系。24小时热线:18380697622