Industry: Glass & glass fiber | Reference site: glass fiber plant export project in Poland | Equipment: power control cabinet with ST200 single-phase SCR power controller 150 A inside
A Kulun Electric power control cabinet is applied in a glass fiber plant export project in Poland, serving heating control of the glass tank furnace fiber drawing section. The cabinet houses an ST200 single-phase SCR power controller rated 150 A, providing stable power regulation for single-phase electric heating loads in the drawing section and meeting glass fiber production requirements for temperature stability, continuous operation and industrial reliability.
1. Project Overview
Industry | Glass & glass fiber, tank furnace fiber drawing |
Reference site | Glass fiber plant export project in Poland |
Equipment | Power control cabinet |
Product inside | ST200 single-phase SCR power controller, 150 A |
Main purpose | Heating power control of the tank furnace fiber drawing section |
Core conditions | High-temperature continuous operation, single-phase electric heating, stable temperature |
Control focus | Smooth power regulation, reliable protection, export project adaptation |
2. Application Background
The tank furnace fiber drawing section is a key stage of glass fiber production, where stable melting and drawing temperatures must be maintained. The stability of heating power control directly affects drawing continuity, process consistency and production status.
In this export project in Poland, the power control cabinet had to adapt to high furnace temperatures, continuous production and single-phase electric heating loads, and to work with the site temperature control system for stable, reliable heating of the drawing section.
3. Requirements & Technical Challenges
For this application, the heating and power control system had to address the following points:
- High temperature stability requirement: The drawing process is sensitive to temperature fluctuation and needs smooth power output from the cabinet.
- Long continuous operation: Glass fiber lines run in long cycles, so the controller must withstand sustained high-load conditions.
- Single-phase heating load control: The on-site heating circuit is relatively high power and requires stable control from the ST200 150 A single-phase unit.
- Export project adaptation: The cabinet must meet overseas delivery requirements in electrical design, cabinet layout, wiring and maintenance.
- System linkage: The cabinet must coordinate with temperature controllers, PLC or supervisory systems for automated heating control of the process section.
4. KULUN Solution
Kulun Electric supplied a power control cabinet housing an ST200 single-phase SCR power controller (150 A) for heating control of the glass tank furnace fiber drawing section.
The cabinet centrally handles power regulation, protection and field wiring integration for the single-phase heating circuit, and works with the temperature control system to control the drawing section temperature — suitable for continuous heating production in the glass fiber industry.
Key Features of the Solution
- ST200 150 A single-phase regulation. Suits single-phase electric heating loads of the tank furnace drawing section and covers higher-power heating circuits.
- Cabinet integration. Power regulation, protection, wiring and cooling are integrated in one cabinet for easy installation, maintenance and export delivery.
- Smooth, controllable output. Output is regulated by the temperature control signal, reducing temperature fluctuation and keeping the drawing process stable.
- Built for continuous production. Designed for long-running glass tank furnace conditions and continuous high-temperature heating sections.
- Easy temperature control linkage. Works with temperature controllers, PLC or supervisory systems for automated heating control of the drawing section.
- Industrial reliability. Adapts to high temperatures, continuous operation and complex electrical environments of glass fiber sites.
5. Reference Projects
The power control cabinet is applied in a glass fiber plant export project in Poland, serving heating control of the glass tank furnace fiber drawing section.
Glass fiber plant in Poland | Tank furnace fiber drawing section
In this project, the Kulun cabinet is configured around the drawing process requirements for temperature stability, continuous operation and single-phase heating load control. The ST200 single-phase 150 A controller acts as the core power control unit inside the cabinet, working with the site temperature control system for heating power regulation of the drawing section.
6. Project Site

Power control cabinet applied in the tank furnace fiber drawing section of a glass fiber plant in Poland
7. Results
After the cabinet was applied to the tank furnace fiber drawing section, the single-phase electric heating system gained smooth, reliable power output that meets site requirements for temperature stability and continuous production.
- Meets single-phase electric heating power control requirements of the drawing section;
- ST200 150 A rating fits higher-power heating circuits;
- Helps reduce heating power fluctuation and improve drawing temperature stability;
- Cabinet integration simplifies installation and maintenance for export projects;
- Meets continuous operation requirements of glass fiber production lines.
Note: Actual performance varies with furnace structure, heating load, temperature control system, site grid conditions, cooling environment and process requirements.
8. Applicable Scenarios
Power control cabinets with ST200 single-phase SCR power controllers can be configured by current rating, cabinet structure and site control requirements for a range of glass fiber and industrial electric heating applications.
- Glass tank furnace fiber drawing sections
- Electric heating systems of glass fiber production lines
- Power control of single-phase resistance heating loads
- Power control cabinet packages for export projects
- Industrial heating equipment requiring stable temperature control and continuous operation
9. FAQ
Can the ST200 single-phase 150 A controller be used in a tank furnace fiber drawing section?
Yes. The ST200 single-phase 150 A SCR power controller suits single-phase electric heating loads of the drawing section and provides stable power control inside a cabinet.
Why does glass fiber tank furnace drawing need a power control cabinet?
The drawing section needs stable temperature and continuous heating. A cabinet centrally handles power regulation, protection and wiring integration, simplifying maintenance and system linkage.
What should be noted when specifying a cabinet for an export project?
Confirm input voltage, load power, current rating, control signal, cabinet dimensions, cooling method, wiring standards, site environment and applicable project standards.
What parameters are needed to specify a controller for glass fiber heating?
Typically input voltage, load type, load power, rated current, number of heating zones, control mode, temperature control system, cooling conditions and installation space.
Can Kulun configure power control cabinets for glass fiber projects?
Yes. Kulun Electric can configure APR series SCR power controllers and cabinet solutions according to load capacity, control mode, cabinet requirements and site conditions of tank furnaces, drawing sections and industrial electric heating projects.