KULUN / SCR Power Controller

TTPR Three-phase SCR Power Controller (Standard)

KULUN TTPR: standard three-phase SCR power controller for annealing, sintering and drying ovens and glass tank furnaces. 25-3000 A.

Output Voltage Range0–100% of input voltage
Output Current Range25–3000 A

产品特征

  • Constant voltage, constant current and constant power closed-loop control

  • Zero-crossing, phase-shift and combined control

  • Rated current 25–3000 A for three-phase loads of different capacities

  • Analog, digital and communication setpoints; connects to PLC and DCS systems

  • Protection: mains fault, overcurrent, load break, mains frequency anomaly and thyristor overheating

  • Optional RS485 MODBUS and PROFIBUS interfaces

技术参数

ItemSpecification
Product typeStandard three-phase thyristor (SCR) power controller
Mains inputThree-phase AC 260–440 V, 40–65 Hz
Control supplyAC 220 V ±10%, 1 A, 40–65 Hz
Output voltage0–100% of input voltage
Rated current25–3000 A
Closed-loop controlConstant voltage, constant current, constant power
Stability≤0.2%
Firing & regulationZero-crossing, phase-shift and combined control
SetpointAnalog, digital or communication setpoint
CommunicationRS485 MODBUS (optional); PROFIBUS (optional)
ProtectionMains fault, overcurrent, load break, mains frequency anomaly, thyristor overheating, etc.

典型应用

Three-phase Industrial Furnaces

Three-phase heating power control for annealing, sintering, quenching and drying furnaces and continuous heat-treatment lines.

Glass & High-temperature Heating

For glass melting, tank furnaces, SiC and MoSi2 elements and resistance heating loops.

Transformers & Inductive Loads

For furnace transformer primary sides, rectifier transformers and power-frequency induction furnaces, confirmed against load parameters.

FAQ

Which three-phase loads suit the TTPR?

Three-phase industrial furnaces, resistance heating, SiC / MoSi2 elements and transformer-type loads after engineering confirmation.

How to choose the rated current?

Confirm against the load’s maximum operating current, duty time, cabinet cooling and margin.

Zero-crossing or phase-shift?

Zero-crossing suits loads with high thermal inertia; phase-shift suits fast regulation or widely varying impedance. Confirm per process.

Can it connect to PLC or DCS?

Analog, digital and communication setpoints are supported; RS485 Modbus and other options depend on the model.

Can inductive loads be selected directly?

Provide transformer capacity, primary voltage, current, wiring and load variation; our engineers confirm firing and protection settings.

选型咨询