Output Voltage Range0–100% of mains input voltage
Output Current RangeAC 10–150 A

Features

  • Three output modes: phase-shift, zero-crossing fixed-cycle and zero-crossing variable-cycle

  • Three closed-loop modes: constant voltage, constant current and constant power

  • Average-value current and voltage measurement as standard

  • Single-row LED digital display

  • Optional Modbus communication

Specifications

Input

Mains supply

Single-phase AC 110–440 V, 45–65 Hz

Control supply

DC 24 V

Output

Output voltage

0–100.0% of mains input voltage

Output current

AC 10–150 A

Performance

Control stability

Better than 0.2%

Control accuracy

Better than 1%

Key features

Closed-loop mode

Open loop, constant current, constant voltage or constant power, selectable

Firing mode

Phase-shift, zero-crossing fixed-cycle, zero-crossing variable-cycle

Setpoint signal

Analog, keypad digital or communication setpoint, selectable

Inputs

2 analog inputs, 2 digital inputs

Outputs

1 relay output, NO contact, AC 240 V/3 A, DC 24 V/5 A

Communication

Modbus RTU

Power sharing

Not supported

Temperature PID loop

Not supported

Protection

Mains fault

Protection on mains frequency out of range, undervoltage or input phase loss

Overheating

Protection when thyristor temperature > 85 °C

Overcurrent

Protection when output current reaches the set multiple

Load break

Protection when load current falls below the threshold setting

Typical Applications

Economical Single-phase Heating

For small and medium single-phase resistance heating, drying equipment, packaging machines and simple temperature control units.

OEM Equipment Integration

For space-tight, cost-sensitive integration covering basic power control needs.

Local Heating Loops

For local heat preservation, pipeline tracing, small furnace bodies and auxiliary heating branches.

FAQ

What power range does SMART cover?

Small and medium single-phase heating loops; confirm rated current by model, nameplate and load.

Why a DC 24 V control supply?

The series uses a low-voltage DC control supply; confirm on-site control supply capacity and polarity during selection.

Can it be used for SiC heating?

Check SiC cold/hot resistance, current variation and process requirements for a match.

Is it suitable for complex multi-zone control?

It fits basic single-loop power control; for multi-zone, complex interlocks or advanced communication, evaluate higher configurations.

Installation notes?

Reserve cooling space, avoid dust, corrosive gas and condensation, and size cables and protection devices to the current rating.

Selection Inquiry

Share your industry, load conditions, voltage, current, power range and site environment — our engineers will help you confirm the right configuration.

Inquiry
Leave your requirements and we will get back to you shortly. Hotline: +86-183-8069-7622