MS21-M Soft Starter, Bypass Type, 5.5–630 kW
KULUN MS21-M: standard bypass-type low-voltage AC motor soft starter with microprocessor control, 5.5-630 kW for pumps, fans and crushers.
Features
Specifications
Input | Mains supply | AC 110–440 V, 45–65 Hz |
Control supply | AC 220 V, 50/60 Hz | |
Output | Output type | Bypass type; external bypass contactor required |
Rated range | 5.5–630 kW | |
Operating characteristics | Starting modes | Constant current, voltage ramp, pulse kick-start |
Duty | Short-time duty, max. 10 starts per hour | |
Key features | Stopping modes | Soft stop, coast stop |
Start / stop time | 1–120 s | |
On-line monitoring | Not supported | |
Inputs | 4 digital inputs (run, stop, jog, programmable) | |
Outputs | 2 relay outputs (fault, bypass), NO contact, AC 240 V/3 A, DC 24 V/5 A | |
Communication | Modbus RTU | |
Current transformers | 3 built in | |
Protection rating | IP20 | |
Protection | Mains fault | Protection on mains frequency out of range, undervoltage or input phase loss |
Phase imbalance | Protection when load current exceeds the imbalance threshold | |
Overheating | Protection when thyristor temperature > 85 °C | |
Overcurrent | Protection when output current reaches the set multiple | |
Motor phase loss | Protection when load current falls below the threshold setting |
Typical Applications
The MS21-M is a standard bypass-type low-voltage AC motor soft starter, 5.5–630 kW, with constant-current, voltage-ramp and pulse kick-start modes. Typical applications:
Pumps and fans
Standard three-phase motor starts where soft stop or coast stop is sufficient, with adjustable 1–120 s ramp and up to 10 starts per hour.
Compressors
Constant-current or voltage-ramp starting limits inrush on compressor drives; an external bypass contactor is required after start-up.
General three-phase motor drives
Crushers, conveyors and similar loads driven from AC 110–440 V mains, with 4 digital inputs, 2 relay outputs and Modbus RTU.
FAQ
How to confirm output voltage and current range?
AC 110–440 V (mains); 5.5–630 kW (matched motor power).
Which applications does it suit?
Three-phase AC motor drives — compressors, pumps, fans, crushers — with constant current, voltage ramp or pulse kick-start modes for heavy loads.
What information is needed for selection?
Site voltage, current, load type, control mode, installation conditions and process requirements.