Three output modes: phase-shift, zero-crossing fixed-cycle and zero-crossing variable-cycle
Independent setpoint and start/stop per channel
Six independent limit functions
One fault relay output
Modbus communication
Six operating panels
SMART-6 Integrated 6-channel Single-phase SCR Power Controller
KULUN SMART-6: six single-phase heating branches in one unit with per-channel setpoint, fault relay and Modbus for ovens and molds.
Features
Specifications
Input | Mains supply | Single-phase AC 110–440 V, 45–65 Hz |
Control supply | AC 220 V | |
Output | Output voltage | 0–100.0% of mains input voltage |
Output current | AC 10–200 A | |
Structure | Wiring | Bottom entry, bottom exit |
Integration | 6 integrated channels, independently controlled | |
Key features | Closed-loop mode | Open loop, constant current, constant voltage or constant power, selectable |
Firing mode | Phase-shift, zero-crossing fixed-cycle, zero-crossing variable-cycle | |
Setpoint signal | Analog, keypad digital or communication setpoint, selectable | |
Inputs | 6 analog inputs | |
Outputs | 1 relay output, NO contact, AC 240 V/3 A, DC 24 V/5 A | |
Communication | Modbus RTU | |
Power sharing | Not supported | |
Temperature PID loop | Not supported | |
Protection | Mains fault | Protection on mains frequency out of range, undervoltage or input phase loss |
Load aging | Not supported | |
Overheating | Protection when thyristor temperature > 85 °C | |
Overcurrent | Protection when output current reaches the set multiple | |
Load break | Protection when load current falls below the threshold setting |
Typical Applications
Compact 6-channel Heating Control
For ovens, packaging machinery, molds and small multi-zone equipment with six centrally controlled single-phase branches.
Modular Equipment Integration
For repetitive multi-loop heating units, easing OEM integration and maintenance.
Zoned Resistance Heating
For resistance wire, far-infrared and auxiliary heating zones; confirm each branch’s parameters independently.
FAQ
SMART-6 or ZERO-6?
Both are 6-channel integrated single-phase controllers; they differ in control supply, interfaces and functions — confirm per project.
Suitable for ovens and mold heating?
Yes for 6-zone single-phase heating; verify per-zone power, current, temperature control and continuous duty.
Can the six channels start/stop independently?
Start/stop and control per channel depend on the model, external signals and system logic.
How to size each channel’s current?
Base it on the branch’s maximum operating current, considering start-up, ambient rise and long-term continuous duty.
Does a single-channel fault affect the others?
Per-branch protection and control logic limit the impact; isolation depends on wiring, protection scheme and fault type.
Selection Inquiry
Share your industry, load conditions, voltage, current, power range and site environment — our engineers will help you confirm the right configuration.