Constant voltage, constant current and constant power closed-loop control
Zero-crossing, phase-shift and combined control
Rated current 25–3000 A for three-phase loads of different capacities
Analog, digital and communication setpoints; connects to PLC and DCS systems
Protection: mains fault, overcurrent, load break, mains frequency anomaly and thyristor overheating
Optional RS485 MODBUS and PROFIBUS interfaces
TTPR Three-phase SCR Power Controller (Standard)
KULUN TTPR: standard three-phase SCR power controller for annealing, sintering and drying ovens and glass tank furnaces. 25-3000 A.
Features
Specifications
| Item | Specification |
|---|---|
| Product type | Standard three-phase thyristor (SCR) power controller |
| Mains input | Three-phase AC 260–440 V, 40–65 Hz |
| Control supply | AC 220 V ±10%, 1 A, 40–65 Hz |
| Output voltage | 0–100% of input voltage |
| Rated current | 25–3000 A |
| Closed-loop control | Constant voltage, constant current, constant power |
| Stability | ≤0.2% |
| Firing & regulation | Zero-crossing, phase-shift and combined control |
| Setpoint | Analog, digital or communication setpoint |
| Communication | RS485 MODBUS (optional); PROFIBUS (optional) |
| Protection | Mains fault, overcurrent, load break, mains frequency anomaly, thyristor overheating, etc. |
Typical Applications
Three-phase Industrial Furnaces
Three-phase heating power control for annealing, sintering, quenching and drying furnaces and continuous heat-treatment lines.
Glass & High-temperature Heating
For glass melting, tank furnaces, SiC and MoSi2 elements and resistance heating loops.
Transformers & Inductive Loads
For furnace transformer primary sides, rectifier transformers and power-frequency induction furnaces, confirmed against load parameters.
FAQ
Which three-phase loads suit the TTPR?
Three-phase industrial furnaces, resistance heating, SiC / MoSi2 elements and transformer-type loads after engineering confirmation.
How to choose the rated current?
Confirm against the load’s maximum operating current, duty time, cabinet cooling and margin.
Zero-crossing or phase-shift?
Zero-crossing suits loads with high thermal inertia; phase-shift suits fast regulation or widely varying impedance. Confirm per process.
Can it connect to PLC or DCS?
Analog, digital and communication setpoints are supported; RS485 Modbus and other options depend on the model.
Can inductive loads be selected directly?
Provide transformer capacity, primary voltage, current, wiring and load variation; our engineers confirm firing and protection settings.
Selection Inquiry
Share your industry, load conditions, voltage, current, power range and site environment — our engineers will help you confirm the right configuration.