MS21-H Soft Starter (High-performance)
KULUN MS21-H: bypass-type low-voltage AC motor soft starter with on-line monitoring, 5.5-630 kW for compressors, pumps, fans and crushers.
Features
Specifications
Input | Mains supply | AC 110–440 V, 45–65 Hz |
Control supply | AC 220 V, 50/60 Hz | |
Output | Output type | Bypass type; external bypass contactor required |
Rated range | 5.5–630 kW | |
Operating characteristics | Starting modes | Constant current, voltage ramp, pulse kick-start |
Duty | Short-time duty, max. 10 starts per hour | |
Key features | Stopping modes | Soft stop, coast stop |
Start / stop time | 1–120 s | |
On-line monitoring | Real-time motor current monitoring with overcurrent protection | |
Inputs | 4 digital inputs (run, stop, jog, programmable) | |
Outputs | 2 relay outputs (fault, bypass), NO contact, AC 240 V/3 A, DC 24 V/5 A | |
Communication | Modbus RTU | |
Current transformers | 3 built in | |
Protection rating | IP20 | |
Protection | Mains fault | Protection on mains frequency out of range, undervoltage or input phase loss |
Phase imbalance | Protection when load current exceeds the imbalance threshold | |
Overheating | Protection when thyristor temperature > 85 °C | |
Overcurrent | Protection when output current reaches the set multiple | |
Motor phase loss | Protection when load current falls below the threshold setting |
Typical Applications
The MS21-H is a bypass-type low-voltage AC motor soft starter with on-line current monitoring, 5.5–630 kW, with constant-current, voltage-ramp and pulse kick-start modes. Typical applications:
Heavy-load starts with current monitoring
Real-time motor current monitoring with overcurrent protection, for loads where start-up current needs to be supervised rather than assumed.
Pumps, fans and compressors
Adjustable 1–120 s start and stop ramps with soft stop or coast stop, up to 10 starts per hour; external bypass contactor required.
Drives integrated into a control system
4 digital inputs, 2 relay outputs and Modbus RTU for run, stop, jog, fault and bypass signals to a PLC or host system.
FAQ
How to confirm output voltage and current range?
AC 110–440 V (mains); 5.5–630 kW (matched motor power).
Which applications does it suit?
Three-phase AC motor drives — compressors, pumps, fans, crushers — with constant current, voltage ramp or pulse kick-start modes for heavy loads.
What information is needed for selection?
Site voltage, current, load type, control mode, installation conditions and process requirements.